国产自拍国产偷拍|广州爱豆文化传媒|色久综合|小尤奈美乳|91最新国产|含羞草麻豆传媒MD0044林予曦|热热热色|爱豆传媒七夕|香蕉网香蕉视频网|飘零影院91制片厂,欧美日韩精品在线,91麻豆一二三四在线,天美传媒网址链接

搜索

您的關(guān)鍵詞

講座報(bào)告 Lectures

當(dāng)前位置: 首頁 · 講座報(bào)告 · 正文
時(shí)間 報(bào)告人
方式 地點(diǎn)

主 講 人:Sio Hang Pun

地  點(diǎn):國家大學(xué)科技園陽光樓北612

主 辦 方:物理與信息工程學(xué)院

開始時(shí)間:2017-10-28 09:00

結(jié)束時(shí)間:2017-10-28 10:00

Monolithic Multi-band Capacitive Micro-machined Ultrasound Transducers (CMUTs) for Photoacoustic Computed Tomography (PACT)

人:Sio Hang Pun, 副教授, 澳門大學(xué)模擬與混合信號(hào)超大規(guī)模集成電路國家重點(diǎn)實(shí)驗(yàn)室

地  點(diǎn):國家大學(xué)科技園陽光樓北612

方:物理與信息工程學(xué)院,福建省醫(yī)療器械和醫(yī)藥技術(shù)重點(diǎn)實(shí)驗(yàn)室

開始時(shí)間:2017-10-28 9:00

結(jié)束時(shí)間:2017-10-28 10:00

要:Among the biomedical imaging modalities, photoacoustic computed tomography (PACT) imaging is one of the fast growing techniques in recent years. In designing the PACT imaging system, a finite bandwidth transducer is one of the limited factors for the overall performance. As the target size is inversely proportional to the dominant frequency components of the generated photoacoustic (PA) signal, a broad bandwidth transducer is desired for different scales imaging. Among various ultrasonic transducers for detection of the PA signal, the use of CMUT as a PA signal detector has several advantages, such as, wider bandwidth and different sizes can be easily fabricated by using the silicon micromachining technology, better matching of acoustic impedance to the human body, easier to form ring type/two dimensional arrays, and facile integration with front-end electronics.

In this talk, we are going to introduce a monolithic multi-band CMUT array for the reception of the wide band PA signals so as to provide high resolution images with high frequency CMUT arrays and present the high signal-to-noise-ratio major structure with low frequency CMUT arrays. To demonstrate its performance, a phantom experiment was conducted to show and evaluate the various qualities of multi-resolution images. In addition, an in vivo mouse model experiment was also carried out for revealing the multi-scale photoacoustic imaging capability with the multi-band CMUTs on biological tissues. From the obtained results, the images from different CMUT arrays could show the structures of the mouse brain in different scales. In addition, the images from the high frequency CMUT arrays were able to reveal the major blood vasculatures, whereas, the images from low frequency CMUT arrays showed the gross macroscopic anatomy of the brain with higher contrast.

上一篇:Wearable biomedical device: From multi-tasking to hardware implementation

下一篇:嘉錫講壇第462期講座:傳統(tǒng)文化與科技創(chuàng)新

關(guān)閉